Browsing Interface
: Welcome guest :
log in
[
Home
| 
Graph
|  ]
KB:
SUMO
Language:
ChineseLanguage
ChinesePinyinWriting
ChineseSimplifiedWriting
ChineseTraditionalLanguage
EnglishLanguage
FrenchLanguage
GermanLanguage
HerbaceousPlant
Hindi
ItalianLanguage
JapaneseLanguage
PortugueseLanguage
SpanishLanguage
SwedishLanguage
WoodyPlant
cb
cz
de
hi
ro
sv
tg
Formal Language:
OWL
SUO-KIF
TPTP
traditionalLogic
KB Term:
Term intersection
English Word:
Any
Noun
Verb
Adjective
Adverb
airTemperature
Sigma KEE - airTemperature
airTemperature
appearance as argument number 1
(
documentation
airTemperature
EnglishLanguage
"(
airTemperature
?AREA ?TEMP) means that the temperature of the air at ?AREA is ?TEMP. Temperature may be expressed in units of
TemperatureMeasure
, including
CelsiusDegree
and
FahrenheitDegree
, among others.")
Mid-level-ontology.kif 25709-25713
(
domain
airTemperature
1
Object
)
Mid-level-ontology.kif 25706-25706
The number 1 argument of
air temperature
is an
instance
of
object
(
domain
airTemperature
2
TemperatureMeasure
)
Mid-level-ontology.kif 25707-25707
The number 2 argument of
air temperature
is an
instance
of
temperature measure
(
instance
airTemperature
BinaryPredicate
)
Mid-level-ontology.kif 25705-25705
air temperature
is an
instance
of
binary predicate
(
subrelation
airTemperature
measure
)
Mid-level-ontology.kif 25708-25708
air temperature
is a
subrelation
of
measure
appearance as argument number 2
(
format
ChineseLanguage
airTemperature
"%2 %n 是 %1 的 air 温度")
domainEnglishFormat.kif 120-120
(
format
ChineseTraditionalLanguage
airTemperature
"%2 %n 是 %1 的 air 溫度")
domainEnglishFormat.kif 119-119
(
format
EnglishLanguage
airTemperature
"%2 is %n an air temperature of %1")
domainEnglishFormat.kif 118-118
(
termFormat
ChineseLanguage
airTemperature
"气温")
domainEnglishFormat.kif 6282-6282
(
termFormat
ChineseTraditionalLanguage
airTemperature
"氣溫")
domainEnglishFormat.kif 6281-6281
(
termFormat
EnglishLanguage
airTemperature
"air temperature")
domainEnglishFormat.kif 6280-6280
antecedent
(=>
(
and
(
climateTypeInArea
?AREA
PolarTypeFClimateZone
)
(
instance
?TIME
TimePosition
)
(
holdsDuring
?TIME
(
airTemperature
?AREA
(
MeasureFn
?TEMP
CelsiusDegree
))))
(
holdsDuring
?TIME
(
greaterThan
10.0 ?TEMP)))
Geography.kif 1597-1603
If
polar typeF climate zone
is a
climate
type in area of
a geographic area
and
a time position
is an
instance
of
time position
and
an entity
celsius degree
(s) is an
air
temperature of
the geographic area
holds
during
the time position
,
then 10.0 is
greater
than
the entity
holds
during
the time position
(=>
(
holdsDuring
?T
(
and
(
located
?H ?L)
(
airTemperature
?L
(
MeasureFn
?T ?TU))
(
attribute
?H
FeelingCold
)))
(
desires
?H
(
holdsDuring
?T
(
and
(
airTemperature
?L
(
MeasureFn
?T2 ?TU))
(
greaterThan
?T2 ?T)))))
emotion.kif 1865-1877
If
a cognitive agent
is
located
at
an entity
and
a time position
the time position
U(s) is an
air
temperature of
the entity
and
feeling hot
is an
attribute
of
the cognitive agent
holds
during
the time position
,
then
the cognitive agent
desire
s
the time position
2
the time position
U(s) is an
air
temperature of
the entity
and
the time position
2 is
greater
than
the time position
holds
during
the time position
(=>
(
holdsDuring
?T
(
and
(
located
?H ?L)
(
airTemperature
?L
(
MeasureFn
?T ?TU))
(
attribute
?H
FeelingHot
)))
(
desires
?H
(
holdsDuring
?T
(
and
(
airTemperature
?L
(
MeasureFn
?T2 ?TU))
(
greaterThan
?T ?T2)))))
emotion.kif 1902-1914
If
a cognitive agent
is
located
at
an entity
and
a time position
the time position
U(s) is an
air
temperature of
the entity
and
feeling hot
is an
attribute
of
the cognitive agent
holds
during
the time position
,
then
the cognitive agent
desire
s
the time position
2
the time position
U(s) is an
air
temperature of
the entity
and
the time position
is
greater
than
the time position
2 holds
during
the time position
(=>
(
holdsDuring
?T
(
and
(
maxDeviceOperatingTemp
?D
(
MeasureFn
?T1 ?U))
(
instance
?U
UnitOfTemperature
)
(
located
?D ?A)
(
attribute
?D
DeviceOn
)
(
airTemperature
?A
(
MeasureFn
?T2 ?U))
(
greaterThan
?T2 ?T1)))
(
modalAttribute
(
holdsDuring
(
ImmediateFutureFn
?T)
(
attribute
?D
DeviceDamaged
))
Likely
))
ComputingBrands.kif 3629-3642
If maximum device operating temperature of
an entity
is
another entity
a third entity
(s) and
the third entity
is an
instance
of
unit of temperature
and
the entity
is
located
at
a fourth entity
and
device on
is an
attribute
of
the entity
and
a fifth entity
the third entity
(s) is an
air
temperature of
the fourth entity
and
the fifth entity
is
greater
than
the other entity
holds
during
a time position
,
then the statement
device damaged
is an
attribute
of
the entity
holds
during
immediately
after
the time position
has the
modal
force
of
likely
(=>
(
holdsDuring
?T
(
and
(
maxDeviceStorageTemp
?D
(
MeasureFn
?T1 ?U))
(
instance
?U
UnitOfTemperature
)
(
located
?D ?A)
(
attribute
?D
DeviceOff
)
(
airTemperature
?A
(
MeasureFn
?T2 ?U))
(
greaterThan
?T2 ?T1)))
(
modalAttribute
(
holdsDuring
(
ImmediateFutureFn
?T)
(
attribute
?D
DeviceDamaged
))
Likely
))
ComputingBrands.kif 3657-3670
If maximum device storage temperature of
an entity
is
another entity
a third entity
(s) and
the third entity
is an
instance
of
unit of temperature
and
the entity
is
located
at
a fourth entity
and
device off
is an
attribute
of
the entity
and
a fifth entity
the third entity
(s) is an
air
temperature of
the fourth entity
and
the fifth entity
is
greater
than
the other entity
holds
during
a time position
,
then the statement
device damaged
is an
attribute
of
the entity
holds
during
immediately
after
the time position
has the
modal
force
of
likely
(=>
(
holdsDuring
?T
(
and
(
minDeviceOperatingTemp
?D
(
MeasureFn
?T1 ?U))
(
instance
?U
UnitOfTemperature
)
(
located
?D ?A)
(
attribute
?D
DeviceOn
)
(
airTemperature
?A
(
MeasureFn
?T2 ?U))
(
lessThan
?T2 ?T1)))
(
modalAttribute
(
holdsDuring
(
ImmediateFutureFn
?T)
(
attribute
?D
DeviceDamaged
))
Likely
))
ComputingBrands.kif 3682-3695
If minimum device operating temperature of
an entity
is
another entity
a third entity
(s) and
the third entity
is an
instance
of
unit of temperature
and
the entity
is
located
at
a fourth entity
and
device on
is an
attribute
of
the entity
and
a fifth entity
the third entity
(s) is an
air
temperature of
the fourth entity
and
the fifth entity
is
less
than
the other entity
holds
during
a time position
,
then the statement
device damaged
is an
attribute
of
the entity
holds
during
immediately
after
the time position
has the
modal
force
of
likely
(=>
(
holdsDuring
?T
(
and
(
minDeviceStorageTemp
?D
(
MeasureFn
?T1 ?U))
(
instance
?U
UnitOfTemperature
)
(
located
?D ?A)
(
attribute
?D
DeviceOff
)
(
airTemperature
?A
(
MeasureFn
?T2 ?U))
(
lessThan
?T2 ?T1)))
(
modalAttribute
(
holdsDuring
(
ImmediateFutureFn
?T)
(
attribute
?D
DeviceDamaged
))
Likely
))
ComputingBrands.kif 3708-3721
If minimum device storagqqqe temperature of
an entity
is
another entity
a third entity
(s) and
the third entity
is an
instance
of
unit of temperature
and
the entity
is
located
at
a fourth entity
and
device off
is an
attribute
of
the entity
and
a fifth entity
the third entity
(s) is an
air
temperature of
the fourth entity
and
the fifth entity
is
less
than
the other entity
holds
during
a time position
,
then the statement
device damaged
is an
attribute
of
the entity
holds
during
immediately
after
the time position
has the
modal
force
of
likely
consequent
(<=>
(
and
(
instance
?X
Region
)
(
holdsDuring
?T
(
property
?X
StandardAmbientTemperaturePressure
)))
(
holdsDuring
?T
(
and
(
airTemperature
?X
(
MeasureFn
298.15
KelvinDegree
))
(
barometricPressure
?X
(
MeasureFn
29.530
InchMercury
)))))
Weather.kif 2663-2673
An entity
is an
instance
of
region
and
the entity
the
attribute
standard ambient temperature and pressure
holds
during
a time position
if and only if 298.15
kelvin degree
(s) is an
air
temperature of
the entity
and 29.530
inch mercury
(s) is a
barometric
pressure of
the entity
holds
during
the time position
(=>
(
holdsDuring
?T
(
and
(
located
?H ?L)
(
airTemperature
?L
(
MeasureFn
?T ?TU))
(
attribute
?H
FeelingCold
)))
(
desires
?H
(
holdsDuring
?T
(
and
(
airTemperature
?L
(
MeasureFn
?T2 ?TU))
(
greaterThan
?T2 ?T)))))
emotion.kif 1865-1877
If
a cognitive agent
is
located
at
an entity
and
a time position
the time position
U(s) is an
air
temperature of
the entity
and
feeling hot
is an
attribute
of
the cognitive agent
holds
during
the time position
,
then
the cognitive agent
desire
s
the time position
2
the time position
U(s) is an
air
temperature of
the entity
and
the time position
2 is
greater
than
the time position
holds
during
the time position
(=>
(
holdsDuring
?T
(
and
(
located
?H ?L)
(
airTemperature
?L
(
MeasureFn
?T ?TU))
(
attribute
?H
FeelingHot
)))
(
desires
?H
(
holdsDuring
?T
(
and
(
airTemperature
?L
(
MeasureFn
?T2 ?TU))
(
greaterThan
?T ?T2)))))
emotion.kif 1902-1914
If
a cognitive agent
is
located
at
an entity
and
a time position
the time position
U(s) is an
air
temperature of
the entity
and
feeling hot
is an
attribute
of
the cognitive agent
holds
during
the time position
,
then
the cognitive agent
desire
s
the time position
2
the time position
U(s) is an
air
temperature of
the entity
and
the time position
is
greater
than
the time position
2 holds
during
the time position
(=>
(
instance
?CTRL
TemperatureControl
)
(
exists
(?DEVICE ?TEMP)
(
and
(
instance
?DEVICE
ElectricDevice
)
(
part
?CTRL ?DEVICE)
(
hasPurpose
?DEVICE
(
exists
(?PROC ?AREA)
(
and
(
instance
?AREA
Region
)
(
instance
?PROC
Process
)
(
instrument
?PROC ?CTRL)
(
result
?PROC
(
airTemperature
?AREA ?TEMP))))))))
engineering.kif 1139-1151
If
an object
is an
instance
of
temperature control
,
then there exist
another object
and
an entity
such that
the other object
is an
instance
of
electric device
and
the object
is a
part
of
the other object
and
the other object
has the purpose there exist
another entity
and
a third entity
such that
the third entity
is an
instance
of
region
and
the other entity
is an
instance
of
process
and
the object
is an
instrument
for
the other entity
and
the entity
is an
air
temperature of
the third entity
is a
result
of
the other entity
(=>
(
instance
?X
AirConditioner
)
(
hasPurpose
?X
(
exists
(?PROC ?TEMP ?AREA)
(
and
(
located
?X ?AREA)
(
instance
?PROC
Process
)
(
instrument
?PROC ?X)
(
result
?PROC
(
airTemperature
?AREA ?TEMP))))))
Mid-level-ontology.kif 26027-26035
If
a physical
is an
instance
of
air conditioner
,
then
the physical
has the purpose there exist
an entity
,
another entity
and
a third entity
such that
the physical
is
located
at
the third entity
and
the entity
is an
instance
of
process
and
the physical
is an
instrument
for
the entity
and
the other entity
is an
air
temperature of
the third entity
is a
result
of
the entity
Show simplified definition (without tree view)
Show simplified definition (with tree view)
Show without tree
Sigma web home
Suggested Upper Merged Ontology (SUMO) web home
Sigma version 3.0 is
open source software
produced by
Articulate Software
and its partners