greaterThan
(=>
(
and
(
totalPipelineInArea
?AREA
(
MeasureFn
?LENGTH ?UNIT))
(
instance
?UNIT
UnitOfLength
)
(
greaterThan
?LENGTH 0))
(
exists
(?PIPE)
(
and
(
instance
?PIPE
Pipeline
)
(
located
?PIPE ?AREA))))
Transportation.kif 694-702
If
a real number
an unit of measure
(s) is a
total
pipeline in area of
a geographic area
and
the unit of measure
is an
instance
of
unit of length
and
the real number
is
greater
than 0,
then there exists
a physical
such that
the physical
is an
instance
of
pipeline
and
the physical
is
located
at
the geographic area
(=>
(
and
(
typicalBloodVolume
?M
(
MeasureFn
?N ?U))
(
holdsDuring
?T
(
bloodVolume
?H
(
MeasureFn
?N2 ?U)))
(
instance
?H ?M)
(
greaterThan
(
MultiplicationFn
?N2 2.0) ?N)
(
lessThan
?N2
(
MultiplicationFn
0.8 ?N)))
(
holdsDuring
?T
(
attribute
?H
SevereBloodLoss
)))
Medicine.kif 5968-5982
If the typical
volume
of blood of a
a kind of mammal
is
a real number
an unit of measure
(s) and
an entity
has
the real number
2
the unit of measure
(s) of blood holds
during
a time position
and
the entity
is an
instance
of
a kind of mammal
and
the real number
2 and 2.0 is
greater
than
the real number
and
the real number
2 is
less
than 0.8 and
the real number
,
then
severe blood loss
is an
attribute
of
the entity
holds
during
the time position
(=>
(
and
(
viewedItemList
?USER ?LIST)
(
instance
?ACCESSING1
AccessingWebPage
)
(
instance
?ACCESSING2
AccessingWebPage
)
(
agent
?ACCESSING1 ?USER)
(
agent
?ACCESSING2 ?USER)
(
instance
?INDEX1
PositiveInteger
)
(
instance
?INDEX2
PositiveInteger
)
(
equal
(
ListOrderFn
?LIST ?INDEX1) ?ACCESSING1)
(
equal
(
ListOrderFn
?LIST ?INDEX2) ?ACCESSING2)
(
greaterThan
?INDEX1 ?INDEX2))
(
earlier
(
WhenFn
?ACCESSING2)
(
WhenFn
?ACCESSING1)))
UXExperimentalTerms.kif 799-817
If
a list
is the list of items
viewed
by
an agent
and
a process
is an
instance
of
accessing web page
and
another process
is an
instance
of
accessing web page
and
the agent
is an
agent
of
the process
and
the agent
is an
agent
of
the other process
and
a positive integer
is an
instance
of
positive integer
and
another positive integer
is an
instance
of
positive integer
and
the positive integer
th
element
of
the list
is
equal
to
the process
and
the other positive integer
th
element
of
the list
is
equal
to
the other process
and
the positive integer
is
greater
than
the other positive integer
,
then the
time
of existence of
the other process
happens
earlier
than the
time
of existence of
the process
(=>
(
holdsDuring
?T
(
and
(
maxDeviceOperatingTemp
?D
(
MeasureFn
?T1 ?U))
(
instance
?U
UnitOfTemperature
)
(
located
?D ?A)
(
attribute
?D
DeviceOn
)
(
airTemperature
?A
(
MeasureFn
?T2 ?U))
(
greaterThan
?T2 ?T1)))
(
modalAttribute
(
holdsDuring
(
ImmediateFutureFn
?T)
(
attribute
?D
DeviceDamaged
))
Likely
))
ComputingBrands.kif 3629-3642
If maximum device operating temperature of
an entity
is
another entity
a third entity
(s) and
the third entity
is an
instance
of
unit of temperature
and
the entity
is
located
at
a fourth entity
and
device on
is an
attribute
of
the entity
and
a fifth entity
the third entity
(s) is an
air
temperature of
the fourth entity
and
the fifth entity
is
greater
than
the other entity
holds
during
a time position
,
then the statement
device damaged
is an
attribute
of
the entity
holds
during
immediately
after
the time position
has the
modal
force
of
likely
(=>
(
holdsDuring
?T
(
and
(
maxDeviceStorageTemp
?D
(
MeasureFn
?T1 ?U))
(
instance
?U
UnitOfTemperature
)
(
located
?D ?A)
(
attribute
?D
DeviceOff
)
(
airTemperature
?A
(
MeasureFn
?T2 ?U))
(
greaterThan
?T2 ?T1)))
(
modalAttribute
(
holdsDuring
(
ImmediateFutureFn
?T)
(
attribute
?D
DeviceDamaged
))
Likely
))
ComputingBrands.kif 3657-3670
If maximum device storage temperature of
an entity
is
another entity
a third entity
(s) and
the third entity
is an
instance
of
unit of temperature
and
the entity
is
located
at
a fourth entity
and
device off
is an
attribute
of
the entity
and
a fifth entity
the third entity
(s) is an
air
temperature of
the fourth entity
and
the fifth entity
is
greater
than
the other entity
holds
during
a time position
,
then the statement
device damaged
is an
attribute
of
the entity
holds
during
immediately
after
the time position
has the
modal
force
of
likely
(=>
(
holdsDuring
?T
(
and
(
systolicBloodPressure
?H
(
MeasureFn
?NS
MmMercury
))
(
diastolicBloodPressure
?H
(
MeasureFn
?ND
MmMercury
))
(
greaterThan
90.0 ?NS)
(
greaterThan
60.0 ?ND)))
(
holdsDuring
?T
(
attribute
?H
LowBloodPressure
)))
Mid-level-ontology.kif 10496-10506
If the
systolic
blood pressure of
an entity
is
another entity
mm mercury
(s) and the
diastolic
blood pressure of
the entity
is
a third entity
mm mercury
(s) and 90.0 is
greater
than
the other entity
and 60.0 is
greater
than
the third entity
holds
during
a time position
,
then
hypotension
is an
attribute
of
the entity
holds
during
the time position
(=>
(
holdsDuring
?T
(
and
(
systolicBloodPressure
?H
(
MeasureFn
?NS
MmMercury
))
(
diastolicBloodPressure
?H
(
MeasureFn
?ND
MmMercury
))
(
greaterThan
?NS 140.0)
(
greaterThan
?ND 90.0)))
(
holdsDuring
?T
(
attribute
?H
HighBloodPressure
)))
Mid-level-ontology.kif 10478-10488
If the
systolic
blood pressure of
an entity
is
another entity
mm mercury
(s) and the
diastolic
blood pressure of
the entity
is
a third entity
mm mercury
(s) and
the other entity
is
greater
than 140.0 and
the third entity
is
greater
than 90.0 holds
during
a time position
,
then
hypertension
is an
attribute
of
the entity
holds
during
the time position
Sigma web home
Suggested Upper Merged Ontology (SUMO) web home
Sigma version 3.0 is
open source software
produced by
Articulate Software
and its partners