Browsing Interface : Welcome guest : log in
Home |  Graph |  LogLearn |  Editor |  ]  KB:  Language: 
  Formal Language: 



KB Term:  Term intersection
English Word: 

  OzoneShield

Sigma KEE - oxygenSaturation
oxygenSaturation

appearance as argument number 1
-------------------------


(instance oxygenSaturation BinaryPredicate) Medicine.kif 1206-1206 oxygen saturation is an instance of binary predicate
(domain oxygenSaturation 1 Human) Medicine.kif 1207-1207 The number 1 argument of oxygen saturation is an instance of human
(domain oxygenSaturation 2 RealNumber) Medicine.kif 1208-1208 The number 2 argument of oxygen saturation is an instance of real number
(documentation oxygenSaturation EnglishLanguage "A measurement of the oxygen saturation in Human Blood, expressed as a percentage of red blood cells that are fully oxygenated. This is often measured by a PuleOximeter.") Medicine.kif 1209-1211 The number 2 argument of oxygen saturation is an instance of real number

appearance as argument number 2
-------------------------


(termFormat EnglishLanguage oxygenSaturation "oxygen saturation") Medicine.kif 1212-1212
(format EnglishLanguage oxygenSaturation "the oxygen saturation of %1 is %2 percent") Medicine.kif 1213-1213

antecedent
-------------------------


(=>
    (oxygenSaturation ?H ?N)
    (and
        (greaterThan ?N 0.0)
        (lessThan ?N 100.0)))
Medicine.kif 1215-1219 If the oxygen saturation of X is Y percent, then Y is greater than 0.0 and Y is less than 100.0
(=>
    (holdsDuring ?T
        (and
            (oxygenSaturation ?H ?N)
            (lessThan ?N 92.0)))
    (holdsDuring ?T
        (attribute ?H Hypoxia)))
Medicine.kif 1221-1227 If the oxygen saturation of X is Y percent and Y is less than 92.0 holds during Z, then Hypoxia is an attribute of X holds during Z

consequent
-------------------------


(=>
    (and
        (instance ?M Measuring)
        (instrument ?M ?PO)
        (agent ?M ?A)
        (patient ?M ?P)
        (instance ?PO PulseOximeter))
    (exists (?N)
        (knows ?A
            (oxygenSaturation ?P ?N))))
Medicine.kif 1241-1250 If X is an instance of measuring, Y is an instrument for X, Z is an agent of X, W is a patient of X, and Y is an instance of pulse oximeter, then there exists V such that Z knows the oxygen saturation of W is V percent


Show simplified definition (without tree view)
Show simplified definition (with tree view)

Show without tree


Sigma web home      Suggested Upper Merged Ontology (SUMO) web home
Sigma version 3.0.0-0a80e6c8 (2026-05-12) is open source software produced by Articulate Software and its partners